Kurzy a certifikace NetApp

All

Data ONTAP SAN Implementation (SANIMP)

2.100 EUR
Days3
9. 10.11. 10. 2017
Praha
ENG

In this workshop course, you learn how to connect Windows® and Linux® hosts to NetApp® SANs via FC and iSCSI protocols.

Audience

Professionals who implement SAN solutions that use NetApp storage systems

Goals

By the end of this course, you should be able to:

  • Define and describe SANs that use FC, FCoE, and iSCSI protocols
  • Configure Windows Server 2012 R2, Red Hat® 6.5, and Data ONTAP® systems for iSCSI connectivity
  • Configure Windows Server 2012 R2, Red Hat 6.5, and Data ONTAP systems for FC and FCoE connectivity
  • Use FC and iSCSI protocols to create and access LUNs from Windows Server 2012 and Red Hat 6.5 systems
  • Create and access a LUN from Windows Server 2012 and Red Hat 6.5
  • Size, clone, copy, move, back up, and recover LUNs on Windows Server 2012 R2 and Red Hat 6.5 systems
  • Troubleshoot SAN connectivity and performance issues

Outline

Module 1: SAN Concepts

  • NetApp SAN
  • SAN Protocols
  • SAN Terminology
  • Implementing SAN
  • Designing and Planning a SAN Solution

Module 2: IP SAN Architecture

  • IP SAN Architecture
  • iSCSI Protocol
  • Implementing IP SAN on Data ONTAP
  • Scaling IP SAN In clustered Data ONTAP

Module 3: Windows IP Connectivity

  • Windows iSCSI Configuration
  • Windows iSCSI Implementation

Module 4: Windows LUN

  • LUN Access Overview
  • Windows Setup
  • Volume Management
  • SnapDrive for Windows

Module 5: Linux IP Connectivity

  • Linux iSCSI Configuration

Module 6: Linux LUN

  • LUN Access Review
  • Linux Setup
  • Volume Management

Module 7: FC SAN Architecture

  • FC SAN Architecture
  • FC SAN Connections
  • FC Protocol

Module 8: FC SAN Fabrics

  • Fabric Design
  • FC Initialization
  • Switch Concepts
  • FC Zoning
  • Scaling FC SAN in clustered Data ONTAP

Module 9: Windows FC Connectivity

  • Windows FC Connectivity
  • Data ONTAP 7-Mode CF Modes
  • Windows Configuration
  • Discovery and Provisioning

Module 10: Unified Connect

  • Unified Connect
  • FCoE-Enabling Technologies
  • End-to-End FCoE Configuration
  • FC-to-FCoE Connectivity

Module 11: Linux FC

  • Linux FC Configuration
  • SnapDrive for Unix

Module 12: LUN Provisioning

  • LUN Provisioning
  • LUN Overwrite Reservations
  • SAN Provisioning Options
  • HOST-Side Space Management
  • Keeping LUNs Online

Module 13: Host Considerations

  • Common Disk Structures
  • Multipathing
  • Clustered Data ONTAP Path Changes
  • Selective LUN Mapping in Clustered Data ONTAP 8.3
  • Queue Depth

Module 14: SAN Management

  • Port and Logical Interface Management
  • LUN Management
  • LUN Mobility
  • Copy Offload
  • LUN Cloning
  • Protecting a LUN
  • Removing a LUN

Module 15: SAN Troubleshooting

  • SAN Troubleshooting
  • Data ONTAP Troubleshooting
  • NetApp Data Center Tools

Appendix A: Windows Miscellaneous

  • Windows CLI
  • Windows Dynamic Disks

Appendix B: Brocade Configuration

  • Switch Configuration
  • Diagnostics
  • Zone Configuration

Prerequisites

  • Certification as a NetApp Data Management Administrator
  • Completion of two courses:
  • SAN Fundamentals on Data ONTAP WBT

o    Either Data ONTAP 7-Mode Administration (D7ADM) or Clustered Data ONTAP 8.3 Administration (D8CADM)

Poptejte kurz u nás

Kurzy
Submit
* Povinné pole